• Install thermal protection without breaking the line
The wraparound sleeve closes over existing hoses, cables and pipes, reducing retrofit labor and equipment downtime.
• Reopen the protected route for maintenance
The hook-and-loop closure gives technicians access to inspect or replace the component beneath the sleeve.
• Protect irregular or difficult assemblies
The open format works around installed connectors, branching routes and long fixed lines that cannot accept a slide-on tube.
• Maintain overlap along exposed sections
Correct closure engagement keeps the coated fiberglass layer positioned over the thermal hazard zone.
1. Wraparound coated fiberglass body
Combines an E-glass substrate with a high-temperature silicone outer layer.
2. Nylon hook-and-loop closure
Enables side-entry installation and repeatable opening during scheduled service.
3. High-Temperature Silicone Coating
The high-temperature silicone rubber coating supports sleeve flexibility, surface integrity and practical installation requirements.
4. Openable and Reusable Design
The openable wraparound construction facilitates inspection and maintenance of underlying lines and allows the sleeve to be reopened and reclosed or replaced as required.
5. Multiple Sizes for Industrial Lines
Available in inner diameters ranging from 10 to 150 mm, suitable for hydraulic hoses, cable bundles, and industrial pipelines of various sizes. Other sizes can be evaluated based on specific project requirements.
| Sleeve Material |
E Fiberglass+ High-temperature Resistant Silicone Rubber |
| Hook and Loop Material |
Nylon |
| Working Temperature |
Continuous working under 500°F (260°C),Peak up to 3000°F(1650°C) |
| Nominal Voltage |
7kV-25kV |
| Flammability |
VW-1 |
| Standard Color |
Red (Color customizable) |
| Cutting Tool |
Scissor |
| Part No |
Inner Diameter |
Thickness (mm)
|
Packing Length (m/spool) |
| mm |
inch |
| GF-VTFH-SR-010-RD |
10 |
3/8" |
1.8 |
20 |
| GF-VTFH-SR-015-RD |
15 |
5/8" |
2.1 |
20 |
| GF-VTFH-SR-020-RD |
20 |
3/4" |
2.4 |
20 |
| GF-VTFH-SR-025-RD |
25 |
1" |
2.6 |
20 |
| GF-VTFH-SR-030-RD |
30 |
1-1/8" |
2.9 |
20 |
| GF-VTFH-SR-035-RD |
35 |
1-3/8" |
3.1 |
20 |
| GF-VTFH-SR-040-RD |
40 |
1-5/8" |
3.4 |
20 |
| GF-VTFH-SR-045-RD |
45 |
1-3/4" |
3.5 |
20 |
| GF-VTFH-SR-050-RD |
50 |
2" |
3.6 |
20 |
| GF-VTFH-SR-055-RD |
55 |
2-1/4" |
3.7 |
20 |
| GF-VTFH-SR-060-RD |
60 |
2-3/8" |
3.8 |
20 |
| GF-VTFH-SR-065-RD |
65 |
2-1/2" |
3.8 |
20 |
| GF-VTFH-SR-070-RD |
70 |
2-3/4" |
4.0 |
20 |
| GF-VTFH-SR-075-RD |
75 |
3" |
4.1 |
20 |
| GF-VTFH-SR-080-RD |
80 |
3-1/8" |
4.2 |
10 |
| GF-VTFH-SR-085-RD |
85 |
3-1/4" |
4.3 |
10 |
| GF-VTFH-SR-090-RD |
90 |
3-1/2" |
4.4 |
10 |
| GF-VTFH-SR-095-RD |
95 |
3-3/4" |
4.5 |
10 |
| GF-VTFH-SR-100-RD |
100 |
4" |
4.6 |
10 |
| GF-VTFH-SR-110-RD |
110 |
4-3/8" |
5.0 |
10 |
| GF-VTFH-SR-120-RD |
120 |
4-3/4" |
5.2 |
10 |
| GF-VTFH-SR-130-RD |
130 |
5-1/8" |
5.5 |
10 |
| GF-VTFH-SR-150-RD |
150 |
6" |
6.0 |
10 |
• Steel and smelting plants
Protects installed hoses and cables near molten-metal handling, hot surfaces and radiant process heat.
• Foundry and casting equipment
Addresses splash and flame exposure on hydraulic lines around furnaces, ladles and transfer equipment.
• Industrial engine compartments
Wraps existing service lines close to exhaust systems, hot housings and confined heat sources.
• Plant retrofit and repair projects
Provides access-friendly protection for fixed piping, cables and hoses already connected in the field.
Measure the largest circumference or outside diameter across the complete installed assembly, including clamps and local transitions. Select enough width to close the sleeve with full hook-and-loop engagement and no exposed gap. Locate the seam away from the most intense heat or direct splash path whenever possible. Check bends, movement, support points and access for reopening. Record the heat-source temperature, distance, exposure duration and whether the hazard is radiation, flame or molten splash. Confirm that the nylon closure is suitable for its actual local temperature and shielding arrangement.
• Diameter and spread width - Standard IDs range from 10 to 150 mm; custom wrap widths can be reviewed from the installed circumference.
• Color and coating - Multiple color options are available to meet customer preferences and project requirements.
• Length and closure layout - Roll length, cut pieces, seam overlap and hook-and-loop placement can be prepared for the assembly plan.
• Identification & Packaging - Product labels, batch identification and customized packaging are available to meet identification and delivery requirements.
• Raw Material Verification - Fiberglass substrate, silicone coating materials and nylon hook-and-loop components are verified against the approved product construction and specifications.
• Coating Quality Inspection - Silicone coating coverage, surface integrity and appearance are inspected for cracks, localized defects and other issues that may affect product quality.
• Stitching and Closure Inspection - Stitching integrity, hook-and-loop alignment, engagement width and closure condition are checked to ensure proper fastening in accordance with the specified installation method.
• Dimensional Verification - Inside diameter, spread width, thickness and cut length are inspected against the applicable tolerances and confirmed product specifications.
• Final Inspection and Traceability - Part number, color, dimensions, length, quantity, labels and packaging are verified before shipment, together with applicable batch records and technical documentation required by the order.
Frequently Asked Questions
01. Can GF-VTFH-SR be installed without disconnecting the hose?
Yes. The sleeve opens along its length, wraps around the installed assembly and closes with the hook-and-loop seam.
02. How should the closure be positioned?
Ensure full engagement and, where practical, orient the seam away from the strongest direct flame, heat or molten-splash path.
03. How do I choose the correct sleeve width?
Measure the maximum circumference of the installed assembly, including fittings, clamps and enlarged sections. Select a sleeve width that provides sufficient coverage, full hook-and-loop engagement and no exposed gaps.
04. Can the sleeve be reopened for routine inspection?
Yes. The hook-and-loop closure allows the sleeve to be opened for visual inspection of the underlying hose, cable or pipe. After inspection, ensure the sleeve is securely reclosed with full engagement and no exposed gaps.
Request a Sample or Quote
Send the protected assembly OD, fitting dimensions, required sleeve length, heat-source temperature, distance from the source, expected exposure time, flame or splash risk, movement, end-fixing method, color and quantity. MJ FLEX can review the GF-FH-SR model, provide the applicable technical documents and arrange a sample or quotation for evaluation.